  • 水平式声学多普勒流速剖面仪600khz.jpg

Horizontal Acoustic Doppler Current Profiler 600 kHz


Online monitoring of river hydrological stations’ flow velocity and discharge, river flow velocity and discharge monitoring, large-scale open-channel flow velocity and discharge monitoring, real-time monitoring of flow fields in harbor waters, flood warning, environmental monitoring at cross-sections, and real-time monitoring of flow velocity and discharge for water diversion projects.


Keyword:

声学多普勒流速剖面仪

HADCP

水平式ADCP

QR code:

Product details


I. Introduction to the Instrument

The LSH10-1P-600S horizontal acoustic Doppler current profiler is typically installed on shore walls or bridge piers. It can perform long-term, unattended measurements and is primarily used for monitoring river flow velocity and discharge, measuring flow velocity and discharge in large open channels, providing flood warnings, monitoring environmental handover sections, and supporting water diversion projects.

II. Product Features

1. Employs broadband technology for high precision and high resolution.

2. Install horizontally on the quay wall or bridge piers.

3. Standard built-in ultrasonic level meter, pressure level meter, and attitude sensor (roll, pitch)

4. Built-in indicator flow velocity algorithm, displaying flow velocity in a two-dimensional horizontal profile with layered visualization.

III. Technical Parameters

I. System Metrics

(1) Number of velocity profile layers: 128

(2) Water layer unit thickness: 0.5 m – 4.0 m

(3) Maximum profile distance: 110 m

(4) Flow velocity measurement accuracy: 0.5% ± 5 mm/s of the measured value

(6) Flow velocity resolution: 1 mm/s

(7) Flow velocity measurement range: ±10 m/s, maximum ±20 m/s

(8) Acoustic water level measurement range: 0.15 m – 30 m

(9) Acoustic water level measurement accuracy: 0.3% ± 3 mm of the measured value

(10) Pressure water level measurement range: 0–20 m

(11) Pressure water level accuracy: 0.5%

(12) Data interface: RS485 output, Modbus protocol

(13) Watertight cable length: 30m standard

(14) Water entry depth: 20 m

(15) Power supply: 12VDC

(16) Average electrical power < 7W

II. Transducer Specifications

(1) Number of flow transducers: 2 flow transducers

(2) Number of depth transducers: 1 pressure water level sensor and 1 acoustic water level sensor

(3) Flow velocity measurement angle: ±22°

(4) Operating frequency: 600 kHz

3. Attitude Sensor

(1) Attitude sensor range: ±40°

(2) Attitude sensor accuracy: ±0.3°

(3) Angular resolution: 0.01°

IV. Other Indicators

(1) Water temperature measurement range: -4℃ to +45℃

(2) Water temperature measurement accuracy: ± 0.2℃

(3) Material: Stainless steel (standard)

(4) Operating temperature: -5℃ to 45℃

(5) Storage temperature: -25℃ to 65℃