Pipeline Network Water Level, Flow Velocity, and Flow Rate Series
Wind speed sensor
Wind speed measurement for environments such as greenhouses, environmental protection, weather stations, ships, docks, and aquaculture.
Classification:
Keyword:
Product details
I. Product Overview
The wind speed transmitter features a compact and lightweight design, making it easy to carry and assemble. Its three-cup design effectively captures accurate wind speed data. The housing is crafted from high-quality aluminum alloy profiles and coated with an electroplated and powder-coated finish, offering excellent corrosion and erosion resistance. This ensures the transmitter remains rust-free even after prolonged use. Combined with a smooth internal bearing system, the transmitter guarantees highly precise data collection. It is widely used for wind speed measurement in environments such as greenhouses, environmental protection sites, meteorological stations, ships, docks, and aquaculture facilities.
II. Functional Features
1. Measurement range: 0–60 m/s, resolution: 0.1 m/s
2. Electromagnetic Interference Protection Measures
3. Adopting a bottom-outlet wiring method completely eliminates the issue of aging rubber gaskets in aviation connectors, ensuring waterproof performance even after long-term use.
4. Equipped with high-performance imported bearings, featuring low rotational resistance and precise measurement.
5. All-aluminum housing with high mechanical strength, high hardness, corrosion resistance, and rust-free—suitable for long-term outdoor use.
6. The equipment’s structure and weight have been carefully designed and distributed, resulting in low rotational inertia and highly responsive performance.
7. Standard ModBus-RTU communication protocol for easy integration.
III. Main Technical Specifications
| DC Power Supply (Default) |
10–30V DC |
| Maximum power consumption |
0.3W (12V power supply) |
| Operating temperature of the transmitter circuit |
-20℃~+60℃, 0%RH~95%RH (non-condensing) |
| Communication interface |
485 Communication (ModBus) Protocol Data bit length: 8 bits Parity check method: None Stop bit length: 1 bit Default ModBus communication address: 1 Baud rate: 2400, 4800 (default), 9600, 19200, 38400, 57600, 115200 |
| Parameter Settings |
Configure via the 485 interface using the provided configuration software. |
| Resolution |
0.1m/s |
| Measurement range |
0–60 m/s |
| Dynamic response time |
≤2s |
| Accuracy |
±(0.2 + 0.03V) m/s, where V represents wind speed. |

Related Downloads
暂无相关下载
Product Message
Contact Us
6F, Jinfeng Building, information photoelectric Park, torch high tech Zone, Huli District, Xiamen, Fujian, China
Follow Us
Mobile phone scan
Follow BOYIDA official account