Pipeline Network Water Level, Flow Velocity, and Flow Rate Series
Acoustic Doppler Current Profiler
Real-time monitoring of flow velocity for small and medium-sized rivers, estuaries, streams, and inlet channels. Offers horizontal or vertical installation options for flow velocity measurement in various environmental conditions.
Keyword:
多普勒流速剖面仪
Product details
Instrument Overview
The Acoustic Doppler Current Profiler employs an advanced transducer planar array configuration for real-time velocity monitoring in small to medium-sized rivers, estuaries, streams, and inlet channels. It offers both horizontal and vertical installation options to accommodate flow velocity measurements in a wide range of environmental conditions.
Performance features
1. Advanced transducer planar array layout
2. Built-in indicator flow rate method
3. Flow rate measurement units at levels 110 and 87
4. Section range: 21 meters
5. Operating frequencies: 2 MHz and 1.9 MHz
6. Supports multiple external level sensors: radar wave, ultrasonic, float-type, and other level sensors (custom-built integrated level sensors).
7. Three installation methods: horizontal installation, diagonal installation, and base-mounted installation.
Technical Parameters
| I. Section Scope | |
| Operating frequency | Dual frequencies of 2 MHz and 1.9 MHz, single beam |
| Section range | High frequency: 2.75 m; low frequency: 21 m |
| Blind spot | High frequency: 0.03 m; low frequency: 0.07 m |
| II. Flow Rate Range | |
| Flow rate range | Default ±4.00 m/s (maximum flow rate 20 m/s) |
| Flow rate accuracy | ±0.5% ± 2 mm/s |
| Flow rate resolution | 0.001m/s |
| Number of unit layers | High frequency: 110 layers; low frequency: 87 layers |
| Unit size | High frequency: 0.025 m; Low frequency: 0.25 m |
| Beam aperture angle | ≤1.4° |
| III. Other Indicator Parameters | |
| Data interface | RS-485 |
| DC voltage | DC12V |
| Power consumption | 3W at 12V, average current: 0.25A |
| Average current | 0.25A |
| Housing material | Steel-reinforced POM and stainless steel |
| Protection level | IP68 waterproof rating |
| Installation method | Horizontal installation, diagonal installation, and base-mounted installation |
| Data output | Water depth, water temperature, stratified flow velocity, attitude angle |
| Calculator dimensions | 241mm x 171mm x 50mm, made of die-cast aluminum, with a 5-inch color display. |
| Accumulator Function | Supports setting river channel shape selection, installation height settings, water level threshold settings, initial flow rate settings, K-value calibration, baud rate settings, and device address functionality. |
| Environmental adaptability | Operating temperature range: -5℃ to +60℃ Storage temperature range: -30℃ to +65℃ |
Next