  • LSH10-1P-22A声学多普勒流速剖面仪(单频ADCP).png

Acoustic Doppler Current Profiler


Real-time monitoring of flow velocity for small and medium-sized rivers, estuaries, streams, and inlet channels. Offers horizontal or vertical installation options for flow velocity measurement in various environmental conditions.


Keyword:

多普勒流速剖面仪

QR code:

Product details


Instrument Overview

The Acoustic Doppler Current Profiler employs an advanced transducer planar array configuration for real-time velocity monitoring in small to medium-sized rivers, estuaries, streams, and inlet channels. It offers both horizontal and vertical installation options to accommodate velocity measurements in a wide range of environmental conditions.

 

Performance Features

1. Advanced transducer planar array configuration
2. Built-in indicator flow rate method
3. Flow velocity measurement unit, 80 layers
4. Section range: 21 meters
5. Operating frequency: 2 MHz
6. Supports multiple external level sensors: radar wave, ultrasonic, float-type, and other level sensors (custom-built integrated level sensors).
7. Three installation methods: horizontal installation, diagonal installation, and base-mounted installation.

 

Technical Parameters

I. Section Scope
Operating frequency 2 MHz, single beam
Section range 21m
Blind spot 0.07m
II. Flow Rate Range
Flow rate range Default ±4.00 m/s (maximum flow rate 20 m/s)
Flow rate accuracy ±0.5% ± 2 mm/s
Flow rate resolution 0.001m/s
Number of unit layers 80th floor
Unit size 0.25m-2m
Beam aperture angle ≤1.4°
III. Other Indicator Parameters
Data interface RS-485
DC voltage DC12V
Power consumption 3W at 12V, average current: 0.25A
Average current 0.25A
Housing material Steel-reinforced POM and stainless steel
Protection level IP68 waterproof rating
Installation method Horizontal installation, diagonal installation, and base-mounted installation
Data output Water depth, water temperature, stratified flow velocity, attitude angle
Calculator dimensions 241mm x 171mm x 50mm, made of die-cast aluminum, with a 5-inch color display.
Accumulator Function Supports setting river channel shape selection, installation height settings, water level threshold settings, initial flow rate settings, K-value calibration, baud rate settings, and device address functionality.
Environmental adaptability Operating temperature range: -5℃ to +60℃ Storage temperature range: -30℃ to +65℃